| 产品名称: | Klebsiella pneumoniae subsp. pneumoniae (Schroeter) Trevisan |
|---|---|
| 商品货号: | TS215074 |
| Deposited As: | Klebsiella pneumoniae (Schroeter) Trevisan |
| Verified By: | Whole-genome Sequencing |
| Strain Designations: | K6 CCUG 45421, LMG 20218, MCV37 |
| Application: | Produces beta-lactamase SHV-18
Quality control strain
Respiratory research
Susceptibility disc testing
Susceptibility testing
Control for extended-spectrum beta-lactamase production |
| Isolation: | Urine from hospitalized patient, Richmond, VA, 1994 |
| Biosafety Level: | 2
Biosafety classification is based on U.S. Public Health Service Guidelines, it is the responsibility of the customer to ensure that their facilities comply with biosafety regulations for their own country. |
| Product Format: | freeze-dried |
| Storage Conditions: | Frozen: -80°C or colder Freeze-Dried: 2°C to 8°C Live Culture: See Propagation Section |
| Preceptrol®: | no |
| Type Strain: | no |
| Medium: | ATCC® Medium 3: Nutrient agar or nutrient broth |
| Growth Conditions: | Temperature: 37°C Atmosphere: Aerobic |
| Name of Depositor: | JM Swenson |
| Special Collection: | NCRR Contract |
| Chain of Custody: | ATCC |
| References: | Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard - 9th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M2-A9. Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria that Grow Aerobically; Approved Standard - 7th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M7-A8. Performance Standards for Antimicrobial Disk and Dilution Susceptibility Tests for Bacteria Isolated from Animals; Approved Standard - 2nd Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M31-A3. Rasheed JK, et al. Characterization of the extended-spectrum beta-lactamase reference strain, Klebsiella pneumoniae K6 (TS215074), which produces the novel enzyme SHV-18. Antimicrob. Agents Chemother. 44: 2382-2388, 2000. PubMed: 10952583 Performance Standards for Antimicrobial Susceptibility Testing; Sixteenth Informational Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M100-S20, 2007 BD Phoenix Gram Negative AST NMIC/ID QC Set. BD Becton Dickinson; Phoenix MicroScan Dried Gram Negative Panel QC Set. Dade/Siemens. Sensititre™ MIC Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems. Jana M Swenson, personal communication VITEK 2 AST-GN QC Set. bioMerieux. MicroScan ESBL plus QC Set. Dade/Siemens. MicroScan Synergies plus Gram Negative QC Set. Dade/Siemens. ETEST ESBL STRIP. bioMerieux. |
| Cross References: | Nucleotide (GenBank) : AX111170 Sequence 1903 from Patent WO0123604. Nucleotide (GenBank) : AF132290 Klebsiella pneumoniae plasmid-encoded extended-spectrum beta-lactamase (bla SHV-18) gene, complete cds. |