| 产品名称: | Escherichia coli (Migula) Castellani and Chalmers |
|---|---|
| 商品货号: | TS215227 |
| Verified By: | Whole-genome Sequencing |
| Classification: | Enterobacteriaceae, Escherichia |
| Strain Designations: | 1532 |
| Application: | Assay of lactam antibiotics beta-lactam antibiotics Evaluation of Mueller-Hinton agar Quality control strain Susceptibility disc testing Susceptibility testing Quality control strain for API, bioMerieux Vitek and Sensititre products |
| Isolation: | Canine, Tennessee |
| Biosafety Level: | 1
Biosafety classification is based on U.S. Public Health Service Guidelines, it is the responsibility of the customer to ensure that their facilities comply with biosafety regulations for their own country. |
| Product Format: | freeze-dried |
| Storage Conditions: | Frozen: -80°C or colder Freeze-Dried: 2°C to 8°C Live Culture: See Propagation Section |
| Preceptrol®: | yes |
| Type Strain: | no |
| Medium: | ATCC® Medium 1165: Nutrient Agar with 100.0 mcg/ml AMP |
| Growth Conditions: | Temperature: 37°C Atmosphere: Aerobic |
| Name of Depositor: | FS Barr |
| References: | Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard - 9th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M2-A9. Protocols for Evaluating Dehydrated Mueller-Hinton Agar; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M6-A2. Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria that Grow Aerobically; Approved Standard - 7th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M7-A8. Performance Standards for Antimicrobial Disk and Dilution Susceptibility Tests for Bacteria Isolated from Animals; Approved Standard - 2nd Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M31-A3. Performance Standards for Antimicrobial Susceptibility Testing; Sixteenth Informational Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M100-S20, 2007 BD Phoenix Gram Negative AST NMIC/ID QC Set. BD Becton Dickinson; Phoenix MicroScan Dried Gram Positive Panel QC Set. Dade/Siemens. MicroScan Dried Gram Negative Panel QC Set. Dade/Siemens. MicroScan Rapid Gram Negative QC Set. Dade/Siemens. Sensititre™ MIC Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems. Susceptibility Testing of Mycobacteria, Nocardiae, and Other Aerobic Actinomycetes; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M24-A. Methods for Antimicrobial Disk Susceptibility Testing of Bacteria Isolated from Aquatic Animals. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M42-A. Methods for Antimicrobial Dilution and Disk susceptibility Testing of Infrequently Isolated or Fastidious Bacteria: Proposed Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M45-A. Medical microbiology -- Susceptibility testing of microbial pathogens to antimicrobial agents -- Part 81: Microdilution; Special requirements for testing of non-fastidious bacteria. Berlin, Germany: Deutsches Institut fur Normung; DIN 58940-81: 2002 Clinical laboratory testing and in vitro diagnostic test systems --- Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices --- Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases. London, UK:British Standards Institution;British Standard BS EN ISO 20776-1:2006. VITEK 2 AST-GN QC Set. bioMerieux. VITEK 2 AST-GP QC Set. bioMerieux. MicroScan Synergies plus Gram Negative QC Set. Dade/Siemens. ETEST ESBL STRIP. bioMerieux. Sensititre™ MIC Breakpoint QC Set/5. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems. |